ࡱ> ;=:;@ !bjbjkk -*  L     $RTV- - -   - *  - r ] o  Wv 0L vY T D <  D  Comments on temporary exemption application under DDA section 55: Tactile Ground Surface Indicators (Queensland Rail) Bashir Ebrahim Client Services Manager Guide Dogs for the Blind Association of Queensland Ph: 07 3264 0210 Fax: 07 3261 7500 Mobile: 0418 157 273 Basis for application QRail raises concerns regarding: Possible hazards for other passengers including people with other disabilities Difficulties of measurement of a required 30% luminance contrast QR indicates that while it wishes to comply as fully as possible with the draft Standards and with relevant Australian Standards, it is concerned regarding issues of safety and of value for money in proceeding with TGSI installation pending clarification of how TGSI are to be applied. Do you support the application from QR that the requirements for installation of hazard and direction TGSI's, as described in the current draft Disability Standard should be exempt until the Australian Transport Council completes its review of the draft Disability Standards for Accessible Public Transport, scheduled for September 2002? No, I do not support the QRail application. The Disability Discrimination Act 1992 requires that we shall not discriminate against any person with a disability. Recent changes to AS1428.4 (2001) relate mainly to clarification of the application and use of TGSIs, as well as additional guidelines for Tactile signage and indicators. The QRail application in no way negates QR from it responsibility to provide fair and equitable and reasonable access to all its patrons, including the safety of vision impaired travellers using its facilities. There has never been any definitive study of the adverse affects of TGSIs to other passengers and people with disabilities. Evidence to date tends to be anecdotal. The issue is of the overuse or incorrect application of TGSIs, and hence sending mixed messages. Research would need to compare accidents or incidents with non-TGSI areas. The normal environment has numerous lips and edges that are greater or equal to the profile of the tiles. These lips and edges are generally safely negotiated by people with disabilities and the general public with relatively little issue being raised. TGSIs should be laid so that there is no likelihood of the edges lifting (this means tiles complying to correct specifications, and not cutting or modifying to suit aesthetic criteria), should be slip resistance tested & classified in accordance with AS/ANZ 4586 (HB 197). Have the top of the domes or bars 4-5mm above the surrounding surface. Comply with the luminance Contrast criteria and ensure that it is maintained throughout the life of the TGSI. (Source AS1428.4 2001) What value are TGSI's to blind people or people with a vision impairment when travelling inside a bus, ferry or train? The addition of TGSIs to bus and rail infrastructure would assist orientation and boost safety. A strip of TGSIs across a doorway would offer some assistance. Where are TGSIs needed to warn vision impaired people of hazards in public transport settings (premises and/or conveyances)? TGSIs are needed in all situations required by the Building Code and Draft Standard in Premises and Infrastructure. These include hazards (platform edges, unseen hazards) or path of travel changes (start/finish of stairs or ramps). This includes consistent use on bus stops & railway platforms to cover bus side mirrors and freight train overhangs. Where are TGSIs needed or useful to assist vision impaired people in direction finding in public transport settings (premises and/or conveyances)? TGSIs should be used in situations where there are locational or directional problems for people who have vision impairments. To provide orientation in open spaces where no other (suitable) tactual / directional cueing is available. To designate a route to be taken to avoid a hazard in the absence of tactile cues. What are the difficulties associated with measuring luminance-contrast and what are the possible solutions to those difficulties? Luminance contrast can be measured in a number of ways. The new standard provides better guidance for this, however, the standards need to prescribe the best method of measurement and calculation of luminance contrast. QRail should be reasonably able to conduct necessary testing, just as the Brisbane City Council does. The first step is for people applying the TGSI standards to consider using materials, e.g. tiles, which comply and source colours which significantly contrasts the surface to which it is being applied. This approach also widens the range of colours able to be used. Summary: When examining the mental effort of mobility for people with vision impairments, it is important to consider that within many environments, e.g. QRails facilities station platforms many of which are unstaffed, the traveller contends with factors such as; extreme masking noise levels which make it difficult to use or detect audio cues, hot humid and windy conditions which make concentrating difficult, platforms which are narrow and varied in length and layout (format), and crowded and busy areas, where pedestrian traffic (both stationary and dynamic) can jostle and create barriers around which the Vision impaired traveller has to find his or her way around, quite often on the incorrect side of the yellow safety line closest to the platform edge, or close to side mirrors of buses as they berth at their designated stops. Fair and equitable ACCESS to all reasonable environments must be a priority for all members of our community, and also to those who visit us from other places. Of what benefit is all the Mobility training, education and so on if there is no way for a person with a vision impairment to negotiate a railway platform, bus transit centre or the simplest foyer or courtyard with black marble and little contrast to spot steps or edges, given those factors mentioned above (to name just a few). We do not need peace-meal efforts or after thoughts. What is needed is appropriate consultation, research and pre-planning. TGSIs should used as per Building Code and Standard in all Premises and Infrastructure. Standards Australia must arrive at a position for use of TGSIs in Conveyances, should define how they expect their required minimum contrast to be measured and calculated for required Luminance contrast in order to ensure a uniform National approach. Go for the maximum standard rather than minimum effort. wx # K L  !AB9:zOZ!!Ⱦh$CJOJQJh$CJOJQJh$B*CJphh$B* CJphh$B*CJph h$CJh$ h$CJwx # E F K L rs !AB^ & F!B9:zOPYZ\];!! & F 8+0P. A!"#$n%8@8 Normal_HmH sH tH ^@^ Heading 1$<@&"5CJKHOJQJmH sH tH u\@\ Heading 2$1$<@&56CJOJQJhtH uX@X Heading 3$<@&CJOJQJmH sH tH uVV Heading 4$@&^5OJQJmH sH tH uDAD Default Paragraph FontVi@V  Table Normal :V 44 la (k@(No List 0U0 Hyperlink>*B*\C@\ Body Text Indent ^OJQJmH sH tH uXR@X Body Text Indent 2 ^B*CJOJQJ*wx #EFKLrs ! A B 9:zOPYZ\];000000000 0 000(000000000(000000(000(00000000 0 0 0 000000w]90]90!B!!8@0(  B S  ?B? B!B&"B|!#Bw"$Bd%BD&B!eeqqoozzB*urn:schemas-microsoft-com:office:smarttagscountry-region8*urn:schemas-microsoft-com:office:smarttagsCity9*urn:schemas-microsoft-com:office:smarttagsState9*urn:schemas-microsoft-com:office:smarttagsplace #(^dejPVSY 1 7 B H :@nx$-3< }ae $&xej333333333GUIDE DOGS QUEENSLANDGUIDE DOGS QUEENSLANDGUIDE DOGS QUEENSLANDGUIDE DOGS QUEENSLANDGUIDE DOGS QUEENSLANDGUIDE DOGS QUEENSLANDGUIDE DOGS QUEENSLANDGUIDE DOGS QUEENSLANDGUIDE DOGS QUEENSLAND David MasonHu  14Q 0zjׄ{* hh^h`OJQJo( hh^h`OJQJo(hh^h`o(()'+0zj14QHu '+ @h ^`OJQJo($@P@UnknownGz Times New Roman5Symbol3& z Arial"1hafaf . .$24d3H(?vComments on temporary exemption application under DDA section 55: Tactile Ground Surface Indicators (Queensland Rail) GUIDE DOGS QUEENSLAND David Mason    Oh+'0<HX lx   wComments on temporary exemption application under DDA section 55: Tactile Ground Surface Indicators (Queensland Rail) ommGUIDE DOGS QUEENSLANDexUIDNormalO David Mason2viMicrosoft Word 10.0@@S @S ՜.+,0` hp|  ? n. A wComments on temporary exemption application under DDA section 55: Tactile Ground Surface Indicators (Queensland Rail) Title  !"#$%&'()+,-./013456789<Root Entry F%o >Data 1TableWordDocument-*SummaryInformation(*DocumentSummaryInformation82CompObjj  FMicrosoft Word Document MSWordDocWord.Document.89q